Description
|
Part No.: 33198
QUADRON®CrossLinkBreaker
NH fuse switch disconnector size 00, 160 A
3-pole, 60 mm system, top and bottom by rotating,
for busbars 12,15,20,25,30x5/10, double-T and triple-T- section
|
System
|
60mm-System classic
|
Product Advantages
|
Adapter system for CrossLink® Technology
Safe and quick refitting of top / bottom connection, live parts remain shock protected
Snap on busbar provides easy and secure contacts
The shock protection cover is in 2 pieces to provide for safe connection of cables
Can be mounted over the flat busbar supports
|
Product Group Subgroup
|
9
24
|
Standards
|
IEC 60947-1:2004
IEC 60947-3:1999
IEC 60947-1:2007
IEC 60947-3:2008
EN 60947-1:2007
EN 60947-3:2009
DIN EN 60947-1/04.08
DIN EN 60947-3/02.10
|
Approvals
|
VDE, IEC (CB), Germanischer Lloyd, GOST, CCC
Type No.: QCB-NH 00
CCC certificate: 2010010302403934
|
Electrical Data
|
690 V AC / 440 V DC / 160 A
type of current AC (50-60Hz) / DC
rated insulation voltage 800V
rated surge withstand capacitiy 6kV
conditional rated short circuit current 50 kA
utilisation categories AC-21B (690 V), AC-22B (500 V), DC-21B (220 V), DC-21B (440 V / 100 A), DC-22B (220 V / 63A)
DC specifications: 2 current paths (L1, L2) in series
with fuse links gL/gG 500V/160A,690V/125A
for fuse links to IEC 60269-2 / DIN VDE 0636-2 size 00 up to 12 W
AC-20B (1000 V), DC-20B (1000 V) pollution degree 2
if application more than DC 440V /AC 690V or AC 160A: do not operate under load
According to the AC and DC switching characteristics and in consideration of the overload conditions, the following distances to earth metal parts have to be provided.
- top 100mm, side 50mm
By using as a disconnector (switching not under load) the mentioned distances are not applicable.
Component unit, front side degree of protection IP30 according to DIN EN 60529; degree of protection near terminal depends on installation.

Adapter module, front side degree of protection IP20 according to DIN EN 60529 (safety against finger touch).
|
Mechanical Data
|
Width x Height x Depth (mm): 106 x 200 x 97
Weight (kg/100): 100
busbar connection: screw less with externally spring-loaded contacts, easy adjustment from 5 to 10 mm busbars and reverse
|
Connections
|
Box terminal:
1,5 -70mm² flexible cables, directly or with wire-end ferrules*, depending on contour of the insulated lead 95mm² could be connectable
1,5 -10mm² solid round
16 -70mm² stranded round
2x10mm², 2x16mm² and 2x25mm² flexible with wire-end ferrules, identical cables placed side by side, crimping square
2x6 -50mm² flexible identical cables placed side by side
la. Cu. 9-13 mm wide
Terminal space 13mm x 13mm
(*flexible cables of maximum cross-section may not fit when using wire-end ferrule)
|
Material Characteristics
|
Main body:
temperature stability 125°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200,

Shock protection cover:
temperature stability 120°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200
Handle:
temperature stability 120°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200
Adapter plate:
temperature stability 125°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200,

Contacts:
spring-loaded contacts,
copper, silver plated
|
Versions
|
See 33 398 for variant with screw M8
See 33 324 for variant with fuse monitoring
See 33 206 for variant with electromechanically fuse monitoring
|
Pack Size
|
1
|